meter

photo of Keysight 86100D digital communication analyzer

Keysight 86100D Infiniium DCA-X Digital Communication Analyzer Mainframe, Modules TDR/TDT and 70GHz RF Oscilloscope

The mainframe comes with module 86118A (Dual 70GHz RF Heads) and module 54754A (for TDR/TDT measurements). Module 86118A (70GHz Sampling Oscillscope with Dual RF Heads) Module, Keysight M54754A (TDR/TDT): 86100D Mainframe Specifications​ Front panel clock trigger Software upgrades for advanced waveform study, including: 86100D-200 for Timing Jitter Analysis; 86100D-201 for Waveform Analysis using extended memory; […]

Keysight 86100D Infiniium DCA-X Digital Communication Analyzer Mainframe, Modules TDR/TDT and 70GHz RF Oscilloscope Read More »

photo of Zurich Instruments HF2LI Multi-frequency Lock-in Amplifier

Zurich Instruments HF2LI Multi-frequency Lock-in Amplifier

The Zurich Instruments HF2LI is a dual-input channel lock-in amplifier that meets a wide range of application needs for test and microsystem prototyping. Not only does the instrument offer high performance, it is capable of simultaneously analyzing incoming signals at up to six frequencies, making it applicable to techniques such as microfluidic-based impedance spectroscopy. The unit is used in combination with a standard Windows controller, through a USB 2.0 high-speed host connection. It includes a flexible graphical user interface and programming interfaces.

Zurich Instruments HF2LI Multi-frequency Lock-in Amplifier Read More »

photo of Stanford Research SR620 Universal Time Interval & Frequency Counter

Stanford Research SR620 Universal Time Interval & Frequency Counter

The Stanford Research SR620 is an interval timer and frequency counter capable of measuring signals from 0.001 Hz to 1.3 GHz. The device is equipped with a graphical output that can be displayed on an oscilloscope and interchanged between a histogram, strip chart of mean values, and jitter. Up to one million samples are used to automatically calculate mean, standard deviation, Allan variance, or minimums and maximums. The input impedance is configurable to either 1 MΩ or 50Ω and supports AC or DC coupling. In frequency counter mode, the SR620’s input sensitivity is 60 mV from 1 to 40 MHz. CMC’s SR620 is equipped with Option 01, which uses an ovenized VCXO timebase.

Stanford Research SR620 Universal Time Interval & Frequency Counter Read More »

photo of Keysight E4990A Impedance Analyzer - for frequency range 20 Hz to 120 MHz

Keysight E4990A Impedance Analyzer – for frequency range 20 Hz to 120 MHz

The E4990A Impedance Analyzer has a frequency range of 20 Hz to 120 MHz. The E4990A provides an industry best 0.045% (typical) basic accuracy over a wide impedance range, with a 40 V built-in DC bias source. The equivalent circuit analysis function supports seven different multi-parameter models and helps you to simulate your own equivalent parameter values of components.
The E4990A supports a wide variety of test accessories that designed to make measurements simple and reliable. Included fixtures are listed below.

Keysight E4990A Impedance Analyzer – for frequency range 20 Hz to 120 MHz Read More »

photo of Agilent E4980A Precision LCR Meter

Agilent E4980A Precision LCR Meter

The Agilent E4980A precision LCR meter provides the best combination of accuracy, speed, and versatility for a wide range of component measurements. Offering fast measurement speed and outstanding performance at both low and high impedance ranges, the E4980A is the ultimate tool for general R&D and manufacturing test of components and materials. LAN, USB and GPIB PC connectivity enhances your design and test productivity.

Agilent E4980A Precision LCR Meter Read More »

Photo of 8970B

Agilent (Hewlett-Packard) 8970B Noise Figure Meter

The Agilent 8970B makes noise figure measurements in the 0 to 30 dB range. Measured noise can be displayed as noise figure or equivalent input noise temperature. Excess Noise Ratio (ENR) data can be entered in data tables on the noise figure meter. The meter uses this information to correct for ENR vs. frequency variations. The 8970B can be used with Agilent 346 (CMC loans the Agilent 346B Solid State Noise Source separately) or 347 noise sources.

Agilent (Hewlett-Packard) 8970B Noise Figure Meter Read More »

Scroll to Top